The All-In-One Superpump - HQ Booster Pumps by Walrus

Feb 20, 2020

Video Chapters (You may choose either section)

00:39Walrus Company Introduction

Walrus CEO Amy Huang talking about the company’s history and philosophy

03:55Evolution of Pressure Booster Pumps

Vice President Samuel Huang talking about different generations of booster pumps from 1984 till today.

08:01Live Demonstration HQ 400

Live comparison of HQ 400 booster pump with a previous model – water flow & noise generation

10:58HQ Series Booster Pump Features

Simon Yen, manager of the international sales dep. explaining the unique features of the HQ Series Booster Bumps

16:58Walrus Marketing Activities

Mark Lin, deputy manager of the international sales dep. sharing Walrus’s marketing strategy and challenges

18:55Ireland Distributor Testimonial

The company’s distributor in Ireland talking about his experiences working with Walrus

22:52Q&A Session

The Walrus team answering some of the most common and most interesting questions regarding the company and the HQ Series Booster Pumps

The All-In-One Superpump - HQ Booster Pumps by Walrus

HQ800

HQ800H

HQ Series Highlights

  • All-in-one design: pump, motor, pressure tank, electronic controller.
  • Compact design & extremely quiet
  • No corrosion & long lifespan
  • 20% lower power consumption

Chat with Walrus

Contact Solpower

Send an Email to Simon Yen, Int. Sales Rep.. Our sales team will get back to you shortly.

Link

To Walrus Channel
(before operation, turn off power switch first.)

HQ TQ Series

Cause 1: No power supply. Remedy: Connect the electricity supply.

Cause 2: Too low/high voltage. Remedy: Check if supply voltage is within ± 10%.

Cause 3: Seized-up pump. Remedy:Place a screwdriver against the shaft end of the motor to check it the rotor will spin freely,and contact your pump supplier.

Cause 1: Seized-up pump. Remedy: Same as above.

Cause 2: Overloaded motor. Remedy: Turn off the power supply and restart or contact your pump supplier.

Cause 3: Poor water supply. Remedy: Check if pump suction inlet is blocked.

Cause 1: Existing pipe is leaking. Remedy: Fix the leakage.

Cause 2: Defective check valve. Remedy: Clean or replace with a new valve.

Cause 3: Pipe suck in air. Remedy: Check the suction pipe and water supply.

Cause 1: Leakage in suction pipe or air in the water. Remedy: Check the suction pipe and water supply.

Cause 2: Discharge flow is too low. Remedy: Set your tap on a higher water flow.

Ineffective grounding. Remedy: Reactivate grounding.

Cause 1: Poor water supply or air suck in. Remedy: 1. Turn off the power supply and open the refilling plug to release the air. Then restart.2. In case of long suction pipes, turn off the power and make sure if water supply is adequate.

Cause 2: Pressure set is too high. Remedy: Adjust pressure per XI.

Cause 3: Flow set is too small. Remedy: Adjust flow switch per XII.

Cause 1: 3-phase motor runs in wrong rotation. Remedy: Switch any of the 2 wires from motor terminal to correct rotation.

Cause 2: Poor water supply. Remedy: check if water supply is adequate and if the suction pipe is blocked.

TP8-PT Series

Cause: The overheating protector is mounted directly on the motor windings. It will stop the motor automatically when the motor temperature is up to abnormal, and restart the motor after the temperature back to normal in 20 minutes.

Remedy:

  • Check the electrical power source, fuse, and circuit breaker.
  • Check if pump is locked by rust or foreign objects.
  • Check if the ventilation of the location is bad for causing the overheating of motor.

Remedy: a. Check and fix the leakage in discharge piping, faucets, and valves.

Cause: The pump's pressure switch has been set accurately. Please do not try to adjust except by qualified personnel.

Remedy:

  • If the motor does not start after any of the faucets or valves are opened, adjust the pressure setting screw to the "+" direction (counterclock- wise) until the motor starts.
  • If the motor fails to stop after all the faucets and valves are closed, adjuts the pressure setting screw to the "-" direction (clockwise) until the motor stops.
  • Repeat step (a) and (b) until the pump work normally.

TP3-PT Series

Cause: The overheating protector is mounted directly on the motor windings. It will stop the motor automatically when the motor temperature is up to abnormal, and restart the motor after the temperature back to normal in 20 minutes.

Remedy:

  • Check the electrical power source,fuse,and circuit breaker.
  • Check if pump is locked by rust or foreign objects.
  • Check if the ventilation of the location is bad for causing the overheating of motor.

Remedy:

  • The pump casing should be full of water,if shortage,please open the red water plug and pour into water anew till quite brimming.